Navigation ×

R & D equipment

SATIMO Anechoic chamber

SATIMO Microwave anechoic chamber can provide all kinds of passive and active testing.

•Measurement includes:Gain, Efficiency, Radiation Power, BER, sensitivity…

•TRP/TIS Measurements conform to CTIA standards.

•Free space & Talk State Testing Ability.

•The test frequency range includes: 400Mhz to 6GHZ


ETS-AMS 8500 Anechoic chamber

 4*4*7 m ETS-AMS 8500 Microwave anechoic chamber can provide all kinds of passive and active testing.

• Include Gain, Efficiency, Radiation Power, BER, sensitivity…

• TRP/TIS Measurements conform to CTIA standards.

• Free space & Talk State Testing Ability.

• The test frequency range includes: 400Mhz to 6GHZ





NFC Test Equipment


SAR Test equipment

EDX2800 RoHS Analytical Detector

It can simultaneously and accurately detect the elements stipulated or related by EU RoHS Directive in 60-300S: lead (Pb), mercury (Hg), cadmium (Cd), chromium (Cr), bromine (Br).


Dimension Testing Projector(No.:JT-300A)

•Antenna Dimension Tolerance Requirements: (+0,-0.15mm)

•Standard Tolerance of Finished Product Dimension Testing Industry


2.5D Image tester



Measurement - Measurable dimensions of geometric figures on a plane (angle, length, diameter, radius, distance from point to line, eccentricity of circle, distance between two circles, etc.)
Graphic Output - It can be output to AutoCAD as a standard engineering drawing according to the shape of the actual workpiece in the real-time image.


Environmental simulation tester



Test description:

Testing antenna products for high and low temperature   Resilience to shocks.

Test conditions:

high temperature:85 ℃,90RH%,48H


Salt spray tester



Testing instructions: Check the environmental ability of metal shrapnel to resist salt spray corrosion.
Test conditions: 1. Salt water test: the laboratory temperature is set at 35 saturated air barrel temperature is set at 47 2. Corrosion test: